Smart IAQ Monitoring

IAQ Sensors &
Smart Ventilation Controls

Traditional ventilation systems work on assumptions. InAir smart IAQ systems work on real-time data. By monitoring air quality parameters continuously, the ventilation system can respond to occupancy, pollutant load, humidity, and CO₂ levels — delivering fresh air when and where it is needed, and reducing energy when it is not.

InAir IAQ Sensors & Smart Ventilation Controls
INA-SENSOR
InAir IAQ Sensor
Technical Specifications
PM2.5 MonitoringReal-time · laser particle counting
TemperatureReal-time monitoring
HumidityReal-time monitoring
VOC SensingStandard VOC sensor
ConnectivityStandard WiFi
App SupportAndroid & iOS
Download specification sheet
INA-THE-SENSOR
Thermostat Controller + IAQ Sensor
Technical Specifications
Temperature Control22°C – 28°C precise regulation
PM2.5 MonitoringReal-time
Temperature & HumidityReal-time monitoring
VOC SensingStandard VOC sensor
ConnectivityStandard WiFi
Required ForAll Heat Pump ERV units
Download specification sheet

InAir IAQ sensors can be integrated with motorised dampers and BMS systems to enable classroom-level, room-level, or zone-level demand-controlled ventilation — as demonstrated in the Bloomingdale International School deployment.

Typical applications

Schools Offices Premium Homes Healthcare Smart Buildings BMS-Integrated Projects
Frequently Asked Questions — IAQ Sensors & Controls
Demand-controlled ventilation (DCV) adjusts fresh air supply in real time based on actual occupancy and pollutant load — rather than running at a fixed speed. When CO₂ rises above a threshold (indicating room is occupied), the ERV increases airflow. When VOC spikes (from cleaning or cooking), the system ramps up to flush the space. When rooms are empty, airflow reduces to save energy. InAir's INA-SENSOR and INA-THE-SENSOR measure all relevant parameters and interface with the ERV unit and motorised dampers.
The INA-THE-SENSOR (thermostat controller + sensor) is required for all InAir Heat Pump ERV (RHP series) units. It provides thermostat control within 22°C–28°C, plus real-time monitoring of PM2.5, temperature, humidity, and VOC. The standard INA-SENSOR (without thermostat function) is suitable for standard ERV units.

How is IAQ Sensors & Smart Ventilation Controls sized?

Sizing starts from the air the space actually needs, not from the size of the room. For occupied spaces that means airflow per person under ASHRAE 62.1 — CO2 is produced by people, so a crowded small room needs more air than an empty large one. For process and extract duties it means the required air changes per hour for the activity. Once the airflow is fixed, the duct route sets the static pressure the unit has to overcome, and those two numbers together select the model.

Three things change the answer in India specifically: outdoor temperature at the design peak, which decides how much heat recovery is worth paying for; outdoor humidity, which decides whether passive recovery is enough or active dehumidification is needed; and local AQI, which sets the filter grade — MERV-13 for ordinary urban particulate, HEPA-13 where AQI regularly passes 200. The city pages give the design figures for fifteen Indian cities.

Where does it install?

Installation is cheapest and least disruptive during construction or renovation, when ducting is concealed inside the ceiling void and no finished surface is disturbed. In a completed interior the same result is reached with surface-run ducting in a boxed soffit, or with a standalone unit that needs only a core-cut through an external wall. A typical residential installation is commissioned in ten to twelve days from order.

Every installation includes a site survey, duct design, commissioning with measured airflow readings, and handover. Send a floor plan to sales@in-air.in and we will size it and quote it.

What does it cost to run?

Two figures matter. The fan draws continuous power, which is small — residential units run in the tens of watts. The larger figure is what the unit saves: recovering heat from the air being exhausted means the incoming air arrives closer to room temperature, so the air conditioner does less work. In a Hyderabad summer, incoming air at 44°C reaching the room at 26–28°C is the difference between an AC that copes and one that runs continuously. Filters are the recurring cost, changed on a schedule that depends on local AQI.

Product questions

What do specifiers ask about this range?

Traditional ventilation systems work on assumptions. InAir smart IAQ systems work on real-time data. By monitoring air quality parameters continuously. In practice that means schools, offices, premium homes, healthcare. Selection starts from the duty the space needs rather than from the size of the room: airflow first, then the static pressure the duct route imposes, then filtration and controls. Get those three right and the equipment follows.
Three things. First, a specification built for Indian conditions. Second, materials chosen for continuous duty. Third, options across the range. What matters is not the datasheet but that the specification is chosen for Indian operating conditions — sustained heat, monsoon humidity and a particulate load that shortens the life of equipment designed for a temperate climate.
Five steps, in order. Define the duty — for iaq sensors & smart ventilation controls that usually means schools, offices, premium homes, healthcare. Calculate the airflow from occupancy under ASHRAE 62.1 rather than from floor area. Check the static pressure the duct route imposes, which is what separates two units of the same rated airflow. Add the filter grade your city calls for. Then validate against the published performance curve.
Yes, and the survey costs nothing. Send a floor plan with occupancy and intended use to sales@in-air.in and an engineer returns the airflow the space needs, which iaq sensors & smart ventilation controls model delivers it, the filter grade your city calls for, and an installed cost. Typical duty for this range is schools, offices, premium homes, healthcare. If the building already ventilates adequately, we say so rather than quoting.