INA-HLN-030B1-DC
RHP · 3000 m³/h
InAir · RHP Heat-Pump Energy Recovery AHU (Sensible & Latent)

INA-HLN-030B1-DC
Heat-Pump Energy Recovery AHU (Sensible & Latent) · 3000 m³/h · Ceiling-mounted
HEAT PUMP
| Rated cooling capacity, kW | 25.6 |
| Rated heating capacity, kW | 26.8 |
| Supply voltage | 380V/3PH/50Hz |
| Fresh air — airflow, m³/h | 3000 |
| Fresh air — E.S.P, Pa | 220 |
| Fresh air — motor, kW | 0.75 |
| Exhaust air — airflow, m³/h | 3000 |
| Exhaust air — E.S.P, Pa | 200 |
| Exhaust air — motor, kW | 0.75 |
| Compressor power, kW | 2.8 |
| Refrigerant | R410A |
| Energy-recovery efficiency | >92% |
| Mounting orientation | Ceiling-mounted |
| Net weight, kg | 380 |


DC-Inverter Heat Pump · Energy Recovery (Sensible & Latent)
25.6 kW cooling · 26.8 kW heating.
R410A · >92% energy recovery · 380V 3-phase.
Adjusted to Indian Subcontinent specifications · −5 °C to +48 °C.
25.6 kW cooling · 26.8 kW heating.
R410A · >92% energy recovery · 380V 3-phase.
Adjusted to Indian Subcontinent specifications · −5 °C to +48 °C.
Fan performance
Indicative curve · fresh-air operating point from datasheet
Two-stage energy recovery (sensible & latent)
Cross-flow core (1st stage) + DX heat pump (2nd stage) · built for Indian conditions
| 1st stage | Cross-flow total energy-recovery core |
| 2nd stage | DC-inverter scroll DX system |
| Compressor | High-pressure chamber scroll |
| Control accuracy | ±2 °C |
| Group control | RS485 · up to 32 AHU/PLC |
| Safety protection | Hi/Lo pressure · overcurrent · phase |
Data per official INAIR datasheet. The latest data can be verified in the current selection software. INAIR reserves the right to introduce changes of parameters and sizes in the process of improvement of the air handling units.
sales@in-air.in
040-49952323
www.in-air.in
040-49952323
www.in-air.in
InAir · RHP Heat-Pump Energy Recovery AHU (Sensible & Latent)

INA-HLN-030B1-DC
Dimensions & air connections · Ceiling-mounted
DIMENSIONS
Unit outline dimensions (mm)
Ceiling-mounted · L×W×H = 2590×1400×850 mm · per official INAIR datasheet

Overall dimensions
| L | W | H | Weight |
|---|---|---|---|
| 2590 | 1400 | 850 | 380 kg |
Air connection sizes (mm)
| Fresh air inlet | Supply outlet |
|---|---|
| 558x623 | 350x300 |
| Return air inlet | Exhaust outlet |
| 558x623 | 350x300 |
OA – outdoor intake · SA – supply air · RA – return air · EA – exhaust air