INA-HLN-060A1-DC

RHP · 6000 m³/h
InAir · RHP Heat-Pump Energy Recovery AHU (Sensible & Latent)
INA-HLN-060A1-DC
Heat-Pump Energy Recovery AHU (Sensible & Latent) · 6000 m³/h · Ceiling-mounted
HEAT PUMP
Rated cooling capacity, kW54.8
Rated heating capacity, kW56.5
Supply voltage380V/3PH/50Hz
Fresh air — airflow, m³/h6000
Fresh air — E.S.P, Pa200
Fresh air — motor, kW2.2
Exhaust air — airflow, m³/h6000
Exhaust air — E.S.P, Pa180
Exhaust air — motor, kW2.2
Compressor power, kW6.7
RefrigerantR410A
Energy-recovery efficiency>92%
Mounting orientationCeiling-mounted
Net weight, kg780
InAir RHP INA-HLN-060A1-DC
Energy recovery diagram
DC-Inverter Heat Pump · Energy Recovery (Sensible & Latent)
54.8 kW cooling · 56.5 kW heating.
R410A · >92% energy recovery · 380V 3-phase.
Adjusted to Indian Subcontinent specifications · −5 °C to +48 °C.
Fan performance
Indicative curve · fresh-air operating point from datasheet
0133326674000533366678000060120180240300 6000 m³/h @ 200 Pa Air volume (m³/h) Static pressure (Pa)
Two-stage energy recovery (sensible & latent)
Cross-flow core (1st stage) + DX heat pump (2nd stage) · built for Indian conditions
1st stageCross-flow total energy-recovery core
2nd stageDC-inverter scroll DX system
CompressorHigh-pressure chamber scroll
Control accuracy±2 °C
Group controlRS485 · up to 32 AHU/PLC
Safety protectionHi/Lo pressure · overcurrent · phase
Indicative figures for this model; confirm with our engineering team before specifying. Data per official INAIR datasheet. The latest data can be verified in the current selection software. INAIR reserves the right to introduce changes of parameters and sizes in the process of improvement of the air handling units.
sales@in-air.in
040-49952323
www.in-air.in
InAir · RHP Heat-Pump Energy Recovery AHU (Sensible & Latent)
INA-HLN-060A1-DC
Dimensions & air connections · Ceiling-mounted
DIMENSIONS
Unit outline dimensions (mm)
Ceiling-mounted · L×W×H = 3720×1240×2380 mm · per official INAIR datasheet
INA-HLN-060A1-DC outline dimensions
Overall dimensions
LWHWeight
372012402380780 kg
Air connection sizes (mm)
Fresh air inletSupply outlet
475x875450x320
Return air inletExhaust outlet
475x875450x320
OA – outdoor intake · SA – supply air · RA – return air · EA – exhaust air
Indicative figures for this model; confirm with our engineering team before specifying. Data per official INAIR datasheet. The latest data can be verified in the current selection software. INAIR reserves the right to introduce changes of parameters and sizes in the process of improvement of the air handling units.
sales@in-air.in
040-49952323
www.in-air.in