← Back to all articles
VOV · ERV · Comparison 6 min read By Abhilash Srinivas, Managing Director – InAir ·

VOV fresh air ventilator vs InAir ERV: specs and energy recovery

VOV's S7 units are HEPA-filtered ventilator fans; InAir's ERVs filter the air and recover 89–90% of its cooling energy. The published figures, side by side.

Last updated:

InAir: VOV fresh air ventilator vs InAir ERV: specs and energy recovery
VOV fresh air ventilatorVOV fresh air ventilator priceVOV vs InAirfresh air ventilator IndiaERV vs ventilator fan

People searching for a VOV fresh air ventilator are usually comparing small wall or ceiling units for a bedroom or flat. This guide sets VOV's published specifications beside InAir's, using only figures each company publishes, and explains the one difference that matters most in an air-conditioned Indian home: whether the unit recovers energy from the air it throws out.

The short answer

From VOV's own product pages (checked 25 November 2026), the VOV S7 and S7 Pro are HEPA-filtered single-room ventilator fans. VOV does not publish a heat exchanger, energy recovery core or recovery efficiency for either model. An InAir energy recovery ventilator (ERV) filters the incoming air and recovers 89–90% of the heat from the outgoing air (Revita and Ventura, tested), so the AC does not have to cool all the fresh air from outdoor temperature.

In that sense a fan-only ventilator behaves more like a filtered exhaust or supply fan than an ERV: it moves and cleans air, but the cooling energy in the outgoing air is lost.

VOV vs InAir: published specifications

VOV S7 ProVOV S7InAir wall-mounted ERVInAir Revita ducted ERV
TypeSingle-room, two-way airflow, wall or ceilingSingle-room, sold as one-way exhaustSingle-room, balanced supply and exhaust, through-wallWhole-home, ducted to each room
Energy / heat recoveryNot publishedNot published92% enthalpy core89–90% (tested)
AirflowSupply 198 m³/h, exhaust 156 m³/hExhaust 156 m³/h (supply figure listed inconsistently)150 m³/h150 to 1,317 m³/h by model
FilterHEPA H13HEPASee spec sheetMERV-13 standard, HEPA-13 optional
NoiseListed as 25, 28 and 36 dB in different places28 dB35 dBPer spec sheet, e.g. 38 dB (INA-MFQR-350, full flow)
PriceUS$279–426 on vovsmart.com; no rupee price foundSame rangeRough estimate; exact figure after a free site surveyRough estimate; exact figure after a free site survey
Seller and service in IndiaNo Indian distributor, warranty or service network publishedSameInAir, Hyderabad headquarters, 15 citiesSame

VOV sources: S7 Pro, S7, core technology and FAQ pages. InAir sources: wall-mounted ERV and Revita spec sheets, company page. If VOV publishes new data, the comparison should be updated; tell us at sales@in-air.in.

Why energy recovery matters in an AC home

Every cubic metre of fresh air a ventilator brings in has to be cooled by the AC from outdoor temperature. Without recovery, on a 38 °C afternoon a 100 m³/h stream adds roughly 0.47 kW of sensible cooling load (1.08 × cfm × ΔT °F), plus moisture in the monsoon. An ERV passes the incoming air across the cool outgoing air first; at 89–90% recovery the added load falls to around 0.05 kW. Over a summer of nights with the bedroom door shut, that is the difference between fresh air that costs little to run and fresh air that the AC fights all night.

HEPA filtration is valuable in Indian cities, and both brands offer it. But filtration and energy recovery are separate jobs. A fan with a HEPA filter cleans the air; it does not pre-cool it.

Questions to ask any fresh air ventilator seller

  • Does the unit have a heat or energy recovery core, and what is its tested recovery efficiency?
  • What are the supply and exhaust airflows at the noise level quoted? (Noise and airflow are linked; a quiet figure at low speed is not the full-flow figure.)
  • Is supply balanced with exhaust, or does the unit only push air in or pull it out?
  • What filter grade is fitted as standard, and what do replacements cost and where are they stocked in India?
  • Who installs and services it in your city, and what is the written warranty?

Which should you choose?

  • Finished flat, one or two rooms: a wall-mounted ERV gives filtered, balanced fresh air with energy recovery, one wall core-cut per room.
  • Whole home under construction or renovation: a ducted Revita ERV serves every bedroom from one unit above the false ceiling.
  • Humid coastal city: an RHP heat pump ERV also cools and dries the fresh air.
  • Just need to clear smells from a toilet or kitchen: an exhaust fan is the right, cheaper tool.

For other brands sold in India, see ERV brands in India compared.

Frequently Asked Questions
VOV's product pages for the S7 and S7 Pro, checked on 25 November 2026, do not publish a heat exchanger, energy recovery core or recovery efficiency. They describe HEPA-filtered ventilator fans. An ERV recovers heat from the outgoing air; InAir's Revita and Ventura recover 89–90% in testing.
It brings in filtered air, but without energy recovery the AC has to cool all of it from outdoor temperature. An ERV pre-cools the incoming air with the outgoing air, so the bedroom gets fresh air with a much smaller added cooling load.
VOV lists the S7 Pro at 25, 28 or 36 dB in different places on the same page. InAir publishes 35 dB for the wall-mounted ERV and, for example, 38 dB at full flow for the Revita INA-MFQR-350. Compare figures at the same airflow.
InAir's India headquarters is in Hyderabad, with installation and service across 15 Indian cities. Book a free site survey to get a quote.
VOV lists the S7 and S7 Pro at US$279–426 on its own website. We could not find a rupee price, an Indian distributor or an Indian warranty. InAir prices depend on the home; as a tentative guide, equipment starts from about ₹1.4 lakh per room, and InAir gives the exact figure after a free site survey.
Ready to breathe better? Start with a free site survey.

Our engineers assess your home or building, recommend the right system and the right filter grade for your city, and give you a clear cost estimate. No obligation.